Home
Cataract
Cornea
Glaucoma
Refractive
Retina
Practice Management
Welcome Guest
Sign In
Register
News
Events
Articles
Product Center
Featured Products
Videos
Register
Sign In
AdGlare Leaderboard
OphthalmologyWeb
Product Center
Retina Products and Equipment
Diagnostic Retinal Imaging
Fundus Photography / Fundus Cameras
Digital Fundus Camera
Digital Fundus Camera
Your search for Fundus cameras returned 22 results.
Showing 7 of 22 products
<<
<
1
2
>
>>
Sort By
Item Name
Company Name
Price
Relevancy
Get quotes for all products
Select All
Select up to 5 products from below to compare or request more information.
Compare
Compare
for selected.
Pictor Plus Portable Ophthalmic Imager
Volk Optical, Inc.
Features:
Pictor
Pictor Plus
Versatile
Images both retina and anterior segments
✔
✔
Portable
Fits in a small briefcase and weighs just 1lb.
✔
✔
Non-mydriatic retinal imaging
Pupils as small as 3mm
✔
✔
Anterior imaging
White or blue (fluoroscein) LED lighting
✔
✔
Storage
More than 1,000 high resolution jpg images on SD card
✔
✔
Simple integration
Images upload to PC via USB connection
✔
✔
Improved image resolution
Meets ISO fundus camera requirements
✔
Auto focus assist
Senses optimal retinal view and automatically takes the image
✔
9 fixation targets
For a variety of retinal images
✔
Patient ID entry via keypad
Facilitates patient records/folders
✔
Additional Wi-Fi PC connectivity
Enhances portable capabilities
✔
Improved glare free anterior segment imaging
✔
Weight (lbs):
Inquire
Pupil Diameter:
Inquire
Power Source:
Inquire
Working Distance:
Inquire
Field Angle/Angle of View:
Inquire
Light Source:
Inquire
Digital Resolution:
Inquire
Camera:
Inquire
Monitor:
Inquire
Power Consumption:
Inquire
Fixation Targets:
Inquire
Database:
Inquire
Dimensions (W × H × D):
Inquire
Refractive Error Compensation:
Inquire
Base Horizontal Movement:
Inquire
Base Vertical Movement:
Inquire
Chinrest Movement:
Inquire
Read More
Inquire
Compare
or
Get quote
for selected.
KOWA VX-10α Combination Non-Mydriatic & Mydriatic Retinal Camera / VK-2 Digital Imaging System
Kowa Optimed, Inc
Features:
Mydriatic & Non-mydriatic operation
Colour & FA modes
Optional FAF mode
Clear view finder & LCD alignment
Small pupil mode
50° and 30° views
Weight (lbs):
78lbs (35.5kg) without video adapter
Pupil Diameter:
Non-mydriatic mode: Ø4.0mm
Mydriatic mode: Ø5.5mm (SP mode: Ø4.0mm)
Power Source:
Inquire
Working Distance:
39mm (between objective lens and cornea)
Field Angle/Angle of View:
Inquire
Light Source:
For observation : Halogen Lamp
For photography : Xenon flash lamp
Digital Resolution:
Inquire
Camera:
Inquire
Monitor:
Inquire
Power Consumption:
Inquire
Fixation Targets:
Internal: 4 fixed dots right or left eye switching (Non-Mydriatic mode)
External: Red / green, blinking
Database:
Inquire
Dimensions (W × H × D):
400 mm x 620 mm x 520
Refractive Error Compensation:
Without compensation : -12D to + 13D
Compensation – : –32D to - 10D
Compensation + : +10D to +35D
Base Horizontal Movement:
Inquire
Base Vertical Movement:
Inquire
Chinrest Movement:
Inquire
Read More
Get quote
View Company Product Page
Compare
for selected.
ZEISS CLARUS 500
ZEISS
Features:
CLARUS 500, the newest ultra-widefield retinal camera from ZEISS, allows clinicians to use color to their diagnostic advantage. ZEISS CLARUS generates images that closely resemble the coloration of the fundus as seen during clinical examination. Color fundus imaging can aid in the diagnosis and documentation of ocular disease, ensuring confidence when evaluating the optic disc, nevi and lesions where color is important.
ZEISS CLARUS 500 captures clear and accurate images from the macula to the far periphery. Early indications of disease can often be subtle and difficult to see through direct observation or low resolution fundus imaging. Leveraging ZEISS optics, CLARUS 500 is an ultra-widefield retinal camera that captures a high-resolution image down to 7 microns.
ZEISS CLARUS 500 allows clinicians to track subtle changes in pathology over time. In addition to true color imaging, it also captures high resolution fundus autofluorescence (FAF) images–FAF-Blue and FAF-Green–and Infrared (IR) and external eye images. Along with an intuitive review software, the ultra-high-resolution of this next-generation retinal camera from ZEISS allows clinicians to manage change with confidence.
Weight (lbs):
50 lbs (20.9 kg)
Pupil Diameter:
2.5 mm
Power Source:
Inquire
Working Distance:
25 mm
Field Angle/Angle of View:
Inquire
Light Source:
Red LED, 585 to 640 nm, Green LED, 500 to 585 nm, Blue LED, 435 to 500 nm, Infrared laser diode, 785 nm
Digital Resolution:
Inquire
Camera:
Inquire
Monitor:
Inquire
Power Consumption:
Inquire
Fixation Targets:
Inquire
Database:
Inquire
Dimensions (W × H × D):
15 x 27 x 18 in (36.2 x 67.6 x 54.6 cm)
Refractive Error Compensation:
Inquire
Base Horizontal Movement:
Inquire
Base Vertical Movement:
Inquire
Chinrest Movement:
Inquire
Read More
Inquire
Compare
for selected.
CIRRUS™ photo 800 - The Versatile Multi-Modality Imager
ZEISS
Features:
MultiMode Navigator- interactive display of fundus image and OCT scans
Precise registration and display of OCT scans with color fundus image
Macular Thickness and Change Analysis
Macular Thickness Normative Data
ONH & RNFL OU Analysis with normative data
Guided Progession Analysis (GPA™)
Weight (lbs):
Inquire
Pupil Diameter:
= 4.0 mm; = 3.3 mm (30° small pupil mode), = 2.0 mm for OCT scans only
Power Source:
Inquire
Working Distance:
40 mm (patient’s eye - front lens)
Field Angle/Angle of View:
Inquire
Light Source:
Inquire
Digital Resolution:
Inquire
Camera:
Inquire
Monitor:
Inquire
Power Consumption:
Inquire
Fixation Targets:
External and internal
Database:
Inquire
Dimensions (W × H × D):
Inquire
Refractive Error Compensation:
Inquire
Base Horizontal Movement:
Inquire
Base Vertical Movement:
Inquire
Chinrest Movement:
Inquire
Read More
Inquire
Compare
or
Get quote
for selected.
Kowa Nonmyd WX-3D Simultaneous Stereoscopic Retinal Camera
Kowa Optimed, Inc
Features:
Inquire
Weight (lbs):
46 lbs (21kg) (Excluding Attached SLR Camera)
Pupil Diameter:
Normal Mode: ?4.0mm
SP Mode:?3.5mm
Stereo Mode: ?4.0mm
Power Source:
Input: AC100-240V 50/60Hz Power Consumption: 150VA
Working Distance:
30mm
Field Angle/Angle of View:
Inquire
Light Source:
Inquire
Digital Resolution:
Inquire
Camera:
Specific Nikon® Digital SLR Camera
Monitor:
Inquire
Power Consumption:
Inquire
Fixation Targets:
Internal: Central, Disc, Macula, mosaic 8 positions
External: Red light (option)
Database:
Inquire
Dimensions (W × H × D):
310 mm x 548 mm x 504 mm
Refractive Error Compensation:
Without Compensation: -12D to +13D
-Compensation: -32D to -10D
+Compensation: +10D to +35D
Base Horizontal Movement:
Inquire
Base Vertical Movement:
Inquire
Chinrest Movement:
55mm (Electric)
Read More
Get quote
View Company Product Page
Compare
or
Get quote
for selected.
VX-20 Combined Mydriatic & Non-Mydriatic Retinal Camera
Kowa Optimed, Inc
Features:
7 in 1 Hybrid retinal imaging system (FAF, FA, RF, Colour, Non-Mydriatic, Auto Mosaic and Anterior picture)
Supports diagnosis of ARMD
Dual magnification split (50° & 30° views)
Complete pan and tilt capability
Simple, easy to use with built-in PC
Ergonomic design
Seamless network connections
Direct print capability
Weight (lbs):
86lbs (39kg)
Pupil Diameter:
Non-mydriatic mode: Ø4.0mm (SP mode: Ø3.5mm)
Mydriatic mode: Ø5.5mm (SP 1 mode: Ø4.0mm, SP2 mode: Ø3.5mm)
Power Source:
Input : AC 120/230V 50/60Hz Power consumption : 250 VA 1500 VA (max.)
Working Distance:
39mm (Between the examined eye and the object lens)
Field Angle/Angle of View:
Non-mydriatic mode: 45°/27°
Mydriatic mode: 50°/ 30° (SP: 45°/27°)
Light Source:
For observation : Halogen Lamp For photography : Xenon flash lamp
Digital Resolution:
Inquire
Camera:
Higher than 12 megapixel CMOS sensor
Monitor:
7 inch wide-screen touch LCD
Power Consumption:
Inquire
Fixation Targets:
Internal: Central/disc/macular/peripheral
External: red/green LED
Database:
Inquire
Dimensions (W × H × D):
390 mmc x 540 mmc x 720 mmc
Refractive Error Compensation:
Without compensation : -12D to + 13D
Compensation – : –32D to - 10D
Compensation + : +10D to +35D
Base Horizontal Movement:
Inquire
Base Vertical Movement:
Inquire
Chinrest Movement:
Inquire
Read More
Get quote
Compare
or
Get quote
for selected.
NW500 Non-Mydriatic Retinal Camera
Topcon Healthcare
Features:
Robotic Fundus camera
Enhanced Image Quality with 12MP Sensor
Small Pupil Photography, ɸ2.0mm or More
Rapid and Simple Capture by Single Touch
Multiple Connectivity Options
50° Field of View
Stereoscopic Photography
Bilateral 2-Field Photography
Weight (lbs):
20 kg (44.1 lb)
Pupil Diameter:
Inquire
Power Source:
Source voltage: AC100 to 240V; Power input: 70 to 120VA; Frequency: 50 to 60Hz
Working Distance:
35.5mm (1.4in)
Light Source:
Inquire
Digital Resolution:
Inquire
Camera:
Inquire
Monitor:
Inquire
Power Consumption:
Inquire
Fixation Targets:
Inquire
Database:
Inquire
Dimensions (W × H × D):
332-426mm (13.1-16.8in)(W) x 519-769mm (20.4-30.3in)(H) x 540-680mm (21.3-26.8in)(D)
Refractive Error Compensation:
Inquire
Base Horizontal Movement:
Inquire
Base Vertical Movement:
Inquire
Chinrest Movement:
Inquire
Read More
Get quote
View Company Product Page
Select All
Select up to 5 products from above to compare or request more information.
Compare
Showing 7 of 22 products
<<
<
1
2
>
>>
Tags:
Please Login or Register to Create Tags
Feedback
Articles
Heidelberg Co-Founder Honored by Optometric Glaucoma Society
Heidelberg Engineering Acquires Medisoft
Volk Releases Pictor Workstation Software Platform
Update on Digital Fundus Cameras
Volk iNview
Smart Multimodal Imaging is Heidelberg Engineering’s Focus During EURETINA and ESCRS 2016
SPECTRALIS Diagnostic Imaging Platform
Volk Optical’s Pictor Plus Portable Imager Used on Charitable Mission in Uganda
Heidelberg Introduces OCT Angiography Module for Spectralis
Heidelberg, Gauss Medical Set Ophthalmic Healthcare IT Joint Venture in China
Digital Fundus Photography: Once Esoteric, Now Essential
The Latest Developments in Ocular Coherence Tomography Systems
Optical Coherence Tomography Angiography – What You Need to Know
Volk iNview Now iPhone SE Compatible
3nethra classic Ophthalmic Imaging Device
Altered Color Perception After Cataract Surgery: An Interactive Case
NIDEK launches VersaCam a Digital Medical Scope
Australian Scientists Discover Genes Involved in Macular Telangiectasia Type 2
UHS Researchers Lead Study Using Heart Drug for Treating CSCR
Eyes Overseas July 2015: The Most Exciting Ophthalmology Products Not Available in the U.S.
Imaging Technologies Update
Moorfields Eye Hospital, Google DeepMind Health Form Medical Research Partnership
Google Uses Deep Machine Learning to Detect Diabetic Retinopathy
Krembil Research Findings Challenge Prevailing View on Retinal Cell Transplantation
New Peptide Holds Promise for Improving Retinal Disease Treatment
Study Examines Successful LA Teleretinal Diabetic Retinopathy Screening Program
Haag-Streit Receives FDA Approval for Fundus Module 300
OD-OS Receives FDA Clearance for Compact Navilas Laser System 577s
Researchers Find Zinc Chelators May Help Regenerate Optic Nerve After Injury
Study Finds Inspecting Red Color Channel May Help Improve Ability to Detect Diabetic Macular Edema
Eye Diagnostics Innovator i-Optics Closes EUR 13.7 Million Financing Round
Ophthalmology 2015: The Year in Review
Genentech's Lucentis Receives FDA Approval for Myopic Choroidal Neovascularization
ADA Publishes Updated Guidelines for Diabetic Retinopathy
Help
Use this product listing in multiple ways:
Click
Get Quote
to receive a quote from the vendor for that product
Check up to 5 products and click to
compare
to view product specifications side by side or
Get quote
to get a quote for all your selected products
Click
Get quotes for all products
at the top of the list to get a quote for all products
advertisement
Related Articles
NIDEK Announces Winners of IMAGEs OF THE YEAR ...
Tuesday, April 11, 2023
FDA Approves SYFOVRE, the First Treatment for ...
Thursday, March 02, 2023
FDA-Cleared FullRange SD-OCT Now Available in ...
Tuesday, February 14, 2023
Helen Keller Foundation Publishes Prevention ...
Monday, January 30, 2023
Maintaining ACE2 in the Gut May Prevent Diabetic ...
Tuesday, January 24, 2023
AdGlare RMR2