Home
Cataract
Cornea
Glaucoma
Refractive
Retina
Practice Management
Welcome Guest
Sign In
Register
News
Events
Articles
Product Center
Featured Products
Videos
Register
Sign In
AdGlare Leaderboard
OphthalmologyWeb
Product Center
Retina Products and Equipment
Diagnostic Retinal Imaging
Fluorescent Retinal Angiography
Fluorescein Angiogram / Fundus Fluorescein Angiography
Fluorescein Angiogram / Fundus Fluorescein Angiography
Showing 6 of 6 products
<<
<
>
>>
Sort By
- select -
Item Name
Company Name
Price
Get quotes for all products
Select All
Select up to 5 products from below to compare or request more information.
Compare
Compare
for selected.
SPECTRALIS Diagnostic Imaging Platform
Heidelberg Engineering, Inc.
Weight (lbs):
Inquire
Working Distance:
Inquire
Photographic Angles:
30° x 30°; optional 55° lens
Film:
Inquire
Image Magnification/Resolution:
10 µm/pixel
Digital Imaging (Y/N):
Yes
Light Source:
820 nm laser; 870 nm SLD
Connectivity:
Yes
Power Consumption:
Inquire
Fixation Targets:
Inquire
Scan Depth:
1.9 mm
Refractive Error Compensation:
Inquire
A-Scan Speed:
Inquire
Axial Resolution:
3.9 µm (digital)
Transverse Resolution:
14 µm
Field Angle/Angle of View:
Inquire
Viewing Magnification:
Inquire
Read More
Inquire
Compare
or
Get quote
for selected.
CX-1 Hybrid Digital Mydriatic/Non-Mydriatic Retinal Camera
Canon Medical Systems
Weight (lbs):
57 pounds (26 kg)
Working Distance:
35 mm from the front of objective lens
Photographic Angles:
Inquire
Film:
Inquire
Image Magnification/Resolution:
Inquire
Digital Imaging (Y/N):
Inquire
Light Source:
Mydriatic: halogen lamp for observation, xenon tube for photography
Non-Mydriatic: IRED for observation, xenon tube for photography
Connectivity:
Inquire
Fixation Targets:
Mydriatic: external type (Standard), internal type (Optional)
Non-Mydriatic: internal fixation target (LED dot matrix, green)
Dimensions (W × H × D):
320 mm (12.6 in) x 577 mm (22.3 in) x 531 mm (20.9 in)
Scan Depth:
Inquire
Refractive Error Compensation:
Inquire
Image Type:
Color, FA, Red Free, Cobalt, FAF
A-Scan Speed:
Inquire
Axial Resolution:
Inquire
Transverse Resolution:
Inquire
Field Angle/Angle of View:
Inquire
Viewing Magnification:
Inquire
Read More
Get quote
Compare
or
Get quote
for selected.
California Ultra-widefield Retinal Imaging System
Optos, Inc.
Weight (lbs):
34 kg / 75 lbs
Working Distance:
Inquire
Photographic Angles:
Inquire
Film:
Inquire
Image Magnification/Resolution:
optomap: 20 µm
optomap plus, af, fa, icg: 14 µm
Digital Imaging (Y/N):
Inquire
Light Source:
Inquire
Connectivity:
Inquire
Power Consumption:
Max. 300 VA
Fixation Targets:
Inquire
Dimensions (W × H × D):
550 x 608 to 632 x 550 mm
Scan Depth:
Inquire
Refractive Error Compensation:
Inquire
Image Type:
optomap and optomap
plus
(red and green laser):
Color composite
green laser View
red laser View
optomap
af
(green laser): autofluorescence
optomap
fa
(blue laser): fluorescein angiography
optomap
icg
(infra-red): indocyanine green angiography
A-Scan Speed:
Inquire
Axial Resolution:
Inquire
Transverse Resolution:
Inquire
Field Angle/Angle of View:
Inquire
Viewing Magnification:
Inquire
Read More
Get quote
Compare
or
Get quote
for selected.
TRC-50DX Mydriatic Retinal Camera
Topcon Healthcare
Weight (lbs):
Inquire
Working Distance:
39mm [1.5 in.]
Photographic Angles:
50°,35°, and 20° angles of coverage
Film:
35mm
Image Magnification/Resolution:
Photographic magnification: With 35 mm camera at zero diopter: 1.84X at 50°, 2.45X at 35° and 4.28X at 20°
Total observation magnification (at zero diopter): 10X at 50°, 13.3X at 35° and 23.3X at 20°
Digital Imaging (Y/N):
Yes
Light Source:
Inquire
Connectivity:
Inquire
Power Consumption:
Inquire
Fixation Targets:
Inquire
Dimensions (W × H × D):
Inquire
Scan Depth:
Inquire
Refractive Error Compensation:
Inquire
Image Type:
Inquire
A-Scan Speed:
Inquire
Axial Resolution:
Inquire
Transverse Resolution:
Inquire
Field Angle/Angle of View:
Inquire
Viewing Magnification:
Inquire
Read More
Get quote
View Company Product Page
Compare
or
Get quote
for selected.
TRC-NW8F Myd/Non-Myd Retinal Camera
Topcon Healthcare
Weight (lbs):
Inquire
Working Distance:
40.7 mm
Photographic Angles:
45°
Film:
Inquire
Image Magnification/Resolution:
12.3MP resolution
Digital Imaging (Y/N):
Yes
Light Source:
Inquire
Connectivity:
Inquire
Power Consumption:
Inquire
Fixation Targets:
Inquire
Dimensions (W × H × D):
Inquire
Scan Depth:
Inquire
Refractive Error Compensation:
Inquire
Image Type:
Inquire
A-Scan Speed:
Inquire
Axial Resolution:
Inquire
Transverse Resolution:
Inquire
Field Angle/Angle of View:
Inquire
Viewing Magnification:
Inquire
Read More
Get quote
View Company Product Page
Compare
for selected.
FF 450
plus
Fundus Camera with VISUPAC™ Digital Imaging System
ZEISS
Weight (lbs):
Inquire
Working Distance:
42mm
Photographic Angles:
Inquire
Film:
Optional
Image Magnification/Resolution:
Dependent on sensor configuration
Digital Imaging (Y/N):
Yes - VISUPAC Digital Imaging and Archive Management
Light Source:
Inquire
Connectivity:
Inquire
Power Consumption:
Inquire
Fixation Targets:
Internal / External
Dimensions (W × H × D):
Inquire
Scan Depth:
Inquire
Refractive Error Compensation:
Inquire
Image Type:
Inquire
A-Scan Speed:
Inquire
Axial Resolution:
Inquire
Transverse Resolution:
Inquire
Field Angle/Angle of View:
Inquire
Viewing Magnification:
Inquire
Read More
Inquire
Select All
Select up to 5 products from above to compare or request more information.
Compare
Tags:
Please Login or Register to Create Tags
Feedback
Articles
Optical Coherence Tomography Angiography – What You Need to Know
Smart Multimodal Imaging is Heidelberg Engineering’s Focus During EURETINA and ESCRS 2016
SPECTRALIS Diagnostic Imaging Platform
Heidelberg Receives FDA Clearance for SPECTRALIS OCT Glaucoma Module Premium Edition
Heidelberg Co-Founder Honored by Optometric Glaucoma Society
Heidelberg Engineering Acquires Medisoft
Heidelberg Delivers 10,000th Spectralis
Heidelberg Introduces OCT Angiography Module for Spectralis
Heidelberg, Gauss Medical Set Ophthalmic Healthcare IT Joint Venture in China
Researchers Use Stem Cell-Derived Retinal Organoids to Assess How Retina Develops
New Research Suggests Underdiagnosis of AMD Not Uncommon in Primary Eye Care
Ohr Pharma Enrolls First Patient in Phase III Wet AMD Clinical Trial
New Study Proves Long-Term Effectiveness of Avastin and Lucentis for Treating AMD
BrightFocus Holds Inaugural Awards
Broccoli-Related Compound May Hold Key in Treating AMD
Study Says Diabetic Vision Loss On the Rise Globally
International Research Team Develops New Cell Culture Model for Earlier AMD Treatment
Ophthalmology 2015: The Year in Review
Wayne State Researchers Reveal New Considerations for Diabetic Peripheral Neuropathy
Acucela Announces End of Clinical Trial Treatment Period for Emixustat Hydrochloride
High School Student Wins International Healthcare Challenge with Ophthalmology Project
Prevent Blindness Honors Ophthalmologist for Diabetic Retinopathy Screening Study
Researchers Find Women’s Sex Drive Pill May Help Prevent Retinal Degeneration
MGH Researcher Finds Overexpression of VEGF-A Promotes AMD, Cataracts
New Study Finds Nerve Damage May Precede Diabetic Retinopathy
NEI Study Shows Intensively Controlling Blood Sugar Levels Can Lower Diabetic Retinopathy Risk
Moorfields Eye Hospital, Google DeepMind Health Form Medical Research Partnership
Researchers Find Alcohol Abuse Drug May Help Prevent Scarring Conjunctivitis
Ophthalmologist Wins Bayer Global Award
USC Roski Eye Institute Publishes Largest Eye Study Among Chinese Americans
Clearside Biomedical Announces Positive Preliminary Trial Results for Macular Edema Treatment
American, Irish Researchers Team Up to Develop Diabetic Retinopathy Treatment
Cardiovascular Drug May Help Reduce Diabetic Retinopathy
Study Examines Link Between Diabetic Retinopathy and Depression
Altered Color Perception After Cataract Surgery: An Interactive Case
Highlights From Hawaiian Eye 2014
Help
Use this product listing in multiple ways:
Click
Get Quote
to receive a quote from the vendor for that product
Check up to 5 products and click to
compare
to view product specifications side by side or
Get quote
to get a quote for all your selected products
Click
Get quotes for all products
at the top of the list to get a quote for all products
advertisement
Related Articles
NIDEK Announces Winners of IMAGEs OF THE YEAR ...
Tuesday, April 11, 2023
FDA Approves SYFOVRE, the First Treatment for ...
Thursday, March 02, 2023
FDA-Cleared FullRange SD-OCT Now Available in ...
Tuesday, February 14, 2023
Helen Keller Foundation Publishes Prevention ...
Monday, January 30, 2023
Maintaining ACE2 in the Gut May Prevent Diabetic ...
Tuesday, January 24, 2023
AdGlare RMR2