DGH-555B Pachette 4

DGH-555B Pachette 4

DGH Technology, Inc.

  • Features:
    • Automatic Report Generation Using Wireless Bluetooth® Technology.
    • Ease of use. Turn on power and the Pachette 4 is ready to take measurements.
    • Accuracy & Reproducibility. Proven measurement algorithm yields accurate, reproducible measurements in a fraction of a second.
    • Obtains and stores up to 25 measurements in less than 2 seconds.
    • Personalized Configuration Memory.
    • Durable Portability. Portable, desktop pachymeter encased in a rubber holster with built-in tilt stand. Probe is detachable for easy cleaning and replacement
    • Mapping Mode for obtaining and storing up to 33 actual and biased corneal mapped measurements.
  • Weight (lbs): Inquire
  • Dimensions (WxHxD): 4.1" (104 mm) x 6.3" (160 mm) x 2.2" (56 mm)
  • IOL Formulas: Inquire
  • Biometry Measurement: Measurement Option: Standard Unit Range (µm): 200 to 1100 µm, 95 to 1100 µm (Flap) Accuracy (µm): 5µm Display Resolution (µm): 1 µm
  • Display : Inquire
  • Power Consumption: Inquire
  • B-Scan Probe: Inquire
  • B-Scan Angle: Inquire
  • B-Scan Depth: Inquire
  • B-Scan Zoom: Inquire
  • Gain/Total Gain Control (TGC): Inquire
  • Biometry Probe: Inquire
  • Biometry Accuracy: Inquire
  • Pachymetry Probe: Inquire
  • Pachymetry Range: Inquire
  • Pachymetry Accuracy: Inquire
Read More
Compare or Get quote for selected.
DGH-55B Pachmate 2

DGH-55B Pachmate 2

DGH Technology, Inc.

  • Features:
    • Automatic Report Generation Using Wireless Bluetooth® Technology.
    • Ease of use. Turn on power and the Pachmate 2 is ready to take measurements.
    • Accuracy & Reproducibility. Proven measurement algorithm yields accurate, reproducible measurements in a fraction of a second.
    • Obtains and stores up to 25 measurements in less than 2 seconds.
    • Personalized Configuration Memory.
    • Durable Portability. Handheld, battery operated, and lightweight.
    • Detachable and Rotatable Probe.
  • Weight (lbs): Inquire
  • Dimensions (WxHxD): 1.6" (41 mm) x 7.1" (181 mm) x 0.9" (23 mm)
  • IOL Formulas: Inquire
  • Biometry Measurement: Measurement Option: Standard Unit Range (µm): 200 to 1100 µm Accuracy (µm): 5µm Display Resolution (µm): 1 µm
  • Display : Inquire
  • Power Consumption: Inquire
  • B-Scan Probe: Inquire
  • B-Scan Angle: Inquire
  • B-Scan Depth: Inquire
  • B-Scan Zoom: Inquire
  • Gain/Total Gain Control (TGC): Inquire
  • Biometry Probe: Inquire
  • Biometry Accuracy: Inquire
  • Pachymetry Probe: Inquire
  • Pachymetry Range: Inquire
  • Pachymetry Accuracy: Inquire
Read More
Compare for selected.
Compact Touch: 3 in 1 Ultrasound System A/B Scan & Pachymetry
  • Features: Improvements in the new generation of Compact Touch include a 15 MHz B probe to increase the quality of the B-scan imaging (resolution increased by 30%), which the platform performs along with A-scan and pachymetry modes. Interactivity is enhanced with DICOM compatibility, WiFi and Bluetooth connectivity and HDMI video output. The sleek, modern design now utilizes a new generation touch screen interface, and the device is fanless and silent as a tablet. User-friendly design and software enhancements improve workflow. The Compact Touch has now received CE Mark.

    Main characteristics:
    • Ultra-compact A/B/P ultrasound system
    • New 15MHz Probe generation
    • DICOM and EMR compatible
  • Weight (lbs): 3.5 kg (7.7 lbs)
  • Dimensions (WxHxD): Weight: 7.7 lbs (3.5 kg)
    Height: 9.7" (24.6 cm)
    Width: 10.6" (26.8 cm)
    Depth: 1.6" (4 cm)
  • IOL Formulas: SRK-T, SRK 2, HOLLADAY, BINKHORST-11, HOFFER-0, HAIGIS
  • Biometry Measurement: Phakic, aphakic, pseudo-phakic
  • Display : Inquire
  • Power Consumption: 100-240 Vac ± 10% single phase without earth
  • B-Scan Probe: 60 mm (2.36")
  • B-Scan Angle: 50 °
  • B-Scan Depth: Inquire
  • B-Scan Zoom: Continuous
  • Gain/Total Gain Control (TGC): 0 to 30 dB
  • Biometry Probe: 11 MHz Probe
  • Biometry Accuracy: 0.03 mm (0.002")
  • Pachymetry Probe: 20 MHz
  • Pachymetry Range: Inquire
  • Pachymetry Accuracy: Inquire
Read More
Inquire
Compare for selected.
MD-1000P Pachymeter

MD-1000P Pachymeter

MEDA CO., LTD.

  • Features: Multiple Corneal Maps with Graphical Display
  • Weight (lbs): Inquire
  • Dimensions (WxHxD): Inquire
  • IOL Formulas: Inquire
  • Biometry Measurement: Biometry Accuracy: ≤±5µm
  • Display : Inquire
  • Power Consumption: Inquire
  • B-Scan Probe: Inquire
  • B-Scan Angle: Inquire
  • B-Scan Depth: Inquire
  • B-Scan Zoom: Inquire
  • Gain/Total Gain Control (TGC): Inquire
  • Biometry Probe: Inquire
  • Biometry Accuracy: Inquire
  • Pachymetry Probe: Inquire
  • Pachymetry Range: Inquire
  • Pachymetry Accuracy: Inquire
Read More
Inquire
Compare for selected.
ODM-1000A/P Ultrasonic Biometer/Pachymeter
  • Features:
    • Automatic and manual gain control modes
    • Immersion Mode measurement
    • Live waveform display
    • Multi-modes measurements
    • Eight groups of measurements to calculate IOL.
    • Portable and sleek.
    • Stores up to 25 measurements by cornea location
    • Build-in thermal printer
      A-Biometer:
    • Gain ≥90dB
    • Gain changeable for users: 0-32dB
    • Accuracy: ≤0.06mm
    • Measure Range: 15-39mm
    • Formulae: SRK-II, SRK/T, BINK-II, Holladay, Hoffer-Q, Haigis
    • Measuring Mode: Auto-Normal, Auto-Cataract, Auto-Aphakic, Auto-Pseudophakic, Manual
      Pachymeter:
    • Frequency: 20MHz
    • Biometry Accuracy: 5 µm
    • Display Resolution: 1µm
    • Measure scope: 200-1100µm
  • Weight (lbs): Inquire
  • Dimensions (WxHxD): Inquire
  • IOL Formulas: SRK-II, SRK/T, BINK-II, Holladay, Hoffer-Q, Haigis
  • Biometry Measurement: Auto-Normal, Auto-Cataract, Auto-Aphakic, Auto-Pseudophakic, Manual
  • Display : Inquire
  • Power Consumption: Inquire
  • B-Scan Probe: Inquire
  • B-Scan Angle: Inquire
  • B-Scan Depth: Inquire
  • B-Scan Zoom: Inquire
  • Gain/Total Gain Control (TGC): Inquire
  • Biometry Probe: Inquire
  • Biometry Accuracy: Inquire
  • Pachymetry Probe: Inquire
  • Pachymetry Range: Inquire
  • Pachymetry Accuracy: Inquire
Read More
Inquire
Compare for selected.
ODM-1000P Pachymeter

ODM-1000P Pachymeter

MEDA CO., LTD.

  • Features:
    • Stores up to 25 measurements by cornea location
    • Central and Peripheral cornea map
    • Build-in thermal printer
    • Accurate and Reliable
    • Portable and sleek
      Pachymeter
    • Frequency: 20MHz
    • Biometry Accuracy: 5 µm
    • Display Resolution: 1µm
    • Measure scope: 200-1100µm
  • Weight (lbs): Inquire
  • Dimensions (WxHxD): Inquire
  • IOL Formulas: Inquire
  • Biometry Measurement: Inquire
  • Display : Inquire
  • Power Consumption: Inquire
  • B-Scan Probe: Inquire
  • B-Scan Angle: Inquire
  • B-Scan Depth: Inquire
  • B-Scan Zoom: Inquire
  • Gain/Total Gain Control (TGC): Inquire
  • Biometry Probe: Inquire
  • Biometry Accuracy: Inquire
  • Pachymetry Probe: Inquire
  • Pachymetry Range: Inquire
  • Pachymetry Accuracy: Inquire
Read More
Inquire
Compare for selected.
Corneo-Gage™ Plus

Corneo-Gage™ Plus

Sonogage, Inc.

  • Features:
    • Completely Portable-move it from lane to lane, office to office
    • No foot pedal, no power cord
    • Battery level indicator
    • Easy To Use-ergonomic probe with continuous read mode
    • Provides Repeatable Readings of the Highest Accuracy
    • Measures the corneal epithelium- optional mode
    • Exclusive 50 MHz solid state transducer
    • Each individual reading is the average of 1000 ultrasonic echoes
    • Individual readings are not averaged-false high values cannot be obtained
    • Automatic calibration verification
    • Built-in dot matrix printer available
    • Built-in IOP correction chart for glaucoma and hypertension patients-optional
  • Weight (lbs): Inquire
  • Dimensions (WxHxD): Inquire
  • IOL Formulas: Built-in IOP correction chart for glaucoma and hypertension patients
  • Biometry Measurement: accurate reproducible corneal thickness measurements
  • Display : Inquire
  • Power Consumption: Inquire
  • B-Scan Probe: Inquire
  • B-Scan Angle: Inquire
  • B-Scan Depth: Inquire
  • B-Scan Zoom: Inquire
  • Gain/Total Gain Control (TGC): Inquire
  • Biometry Probe: Inquire
  • Biometry Accuracy: Inquire
  • Pachymetry Probe: Inquire
  • Pachymetry Range: Inquire
  • Pachymetry Accuracy: Inquire