OCULUS Binoptometer® 4P
OCULUS, Inc.
Features:
Visual Acuity Test -
With Landolt rings (in acc. with DIN EN ISO 8596), numbers, letters, tumbling E and acuity symbols for children (optional).
New: Now also ETDRS Charts are available for the visual acuity test.
Color Vision Test -
Large selection of color plates according to Ishihara and Velhagen-Broschmann colour test plates. The display is calibrated to the exact color temperature, thus guaranteeing ideal color rendering.
Binocular Test -
The binocular vision tests are generated by a modern LCD shutter system, which is very similar to natural visual conditions. Furthermore, a variety of stereo-vision and phoria tests guarantees a reliable evaluation of the binocular vision functions.
Contrast Sensitivity Test -
A program for testing contrast sensitivity under photopic conditions is also integrated. The contrast sensitivity test can be conducted at various visual acuity levels with Landolt rings, letters and numerals as options.
Mesopic Vision and Glare Sensitivity -
Visual performance varies in different light conditions.
To test visual function under mesopic conditions, a Landolt ring is presented in an environment of low light density (0.032 cd/m²), corresponding to the situation of night driving. The Landolt ring (visual acuity level 20/200) is presented in four different contrast stages (1:23 / 1:5 / 1:2.7 / 1:2). Glare sensitivity is tested by simulating the dimmed light of an approaching vehicle. The test with this glare light is also conducted in the four contrast stages.
New: Due to additional corrective lenses in the range of -0,5 D to -3,5 D the possibility to check night myopia is now available.
Peripheral Visual Field Test -
The visual field is tested at seven visual field locations at the right and at the left. Fixation control is done by means of a changing fixation mark in the center of the test screen.
Additional Corrective Lenses -
If asthenopic symptoms are present or if the visual acuity values are abnormal, the additional corrective lenses in the range of +4,5 D to -3,5 D can be used to determine whether an undetected (latent) hyperopia (up to +1,5 D), an age-related long sightedness (presbyopia) or myopia, especially night myopia, exist.
Range of Accommodation Measurement -
Measurement of the range of accommodation can be a valuable tool for deciding whether special eyeglasses for computer users are needed. The Duane test figure makes a speedy and informative measurement possible.
Optotypes for Children -
In addition to the tumbling-E test, additional optotypes for testing the visual acuity of children have been added. These are based on the H-test optotypes.
Read More
Get quote
Compare
for selected.
Adult Near Contrast Test
Good-Lite (Formerly Richmond Products, Inc.)
Features:
Contrast Levels 100%, 25%, 10%, 5%, 2.5%
Both ETDRS Letters and Continuous Reading Examples
20/400 to 20/10 in 17 increments
Shows Snellen in Feet/ Meters, LogMAR, Decimal and Letter Size
Pages tabbed at each contrast level
Includes Instructions, Score Card and Recording Form
Read More
Inquire
Compare
for selected.
Low Contrast Flip Chart with a different sequence of Lea Numbers
Good-Lite (Formerly Richmond Products, Inc.)
Features:
Inquire
Inquire
Compare
for selected.
Low Contrast Flip Chart with Lea Numbers
Good-Lite (Formerly Richmond Products, Inc.)
Features:
Inquire
Inquire
Compare
for selected.
Low Contrast Flip Chart with Lea Symbols
Good-Lite (Formerly Richmond Products, Inc.)
Features:
Inquire
Inquire
Compare
for selected.
Low Contrast Flip Chart with Lea Symbols
Good-Lite (Formerly Richmond Products, Inc.)
Features:
Inquire
Inquire
Compare
for selected.
Pediatric Near Contrast Test
Good-Lite (Formerly Richmond Products, Inc.)
Features:
Provides both Lea Symbols™ and Lea Numbers™
Contrast Levels 100%, 25%, 10%, 5%, 2.5% and 1.25%
To simplify presentation, over-lay template can hide optotypes sizes
Full contrast shows 20/400 to 20/10 in 17 increments, other levels show 15 levels
Shows Optotypes in Snellen Feet and Meters, LogMAR, Decimal and Letter Size
Pages tabbed at each contrast level. Instructions, Score and Recording Forms
Read More
Inquire
Compare
for selected.
Rabin Cone Test
INNOVA Systems, Inc.
Features:
Scores cone function and tracks changes over time
Earlier pathology detection
Rapid disease progression monitoring
Treatment efficacy measurement
Patient-friendly reports graph visual function
Better treatment adherence
Increased supplement prescriptions
Developed in cooperation with the US Air Force
Published, peer-reviewed
Reliable and repeatable
Over 400 in use
Accurate Medicare coding
Validated against Anomoloscope
Fully calibrated
Ideal for the ophthalmic lane or screening room, includes:
Acuity tests
Contrast Sensitivity
Night Vision
Read More
Inquire
Compare
for selected.
Holladay Automated Contrast Sensitivity System™ (HACSS)
M&S Technologies, Inc.
Features:
Testing for CSF Under Glare Conditions
at low, medium or high luminance levels. Can be performed at either mesopic or photopic luminance levels
Preferred Optotypes
; Rotationally symmetric targets and randomly presented optotypes. Eliminates biases from the patient with non-rotational symmetric optical aberrations such as residual astigmatism, trefoil, coma, etc.
ANSI & ISO Guideline Conformance
; Conducts contrast sensitivity testing at (1.5, 3, 6, 12 and 18) cycles per degree and at light levels of 85 cd/m2 (photopic) and 3 cd/m2 (mesopic). Plus, includes all of the options and parameters the agencies require for contrast testing
Conduct Standard Vision Testing
; Integrate with the M&S Smart System comprehensive visual acuity, contrast sensitivity, fixation and video display systems. Approved for clinical trials using the eETDRS and ATS protocols for visual acuity
Quick Test Feature
that reduces test time on patient return visits by starting at 0.3 log units above previous threshold, minimizing test time to less than 3 minutes per eye
Automated-user interactive testing eliminates technician bias or erroneous data
Store multiple test results by patient to track changes in CSF function over time; results can be stored locally or transferred to any media storage device
Graph, compare and print patent results against normative data
Utilizes Smart System integrated database to store and transmit test results within minutes of test completion via internet connections
Read More
Inquire
Compare
for selected.
Linear Sine Wave Grating with Normative Data
M&S Technologies, Inc.
Features:
Utilize automated protocol that provides results with normative data or manually test patients using the M&S Remote Control or Keypad
Measure contrast at ANSI Standard 18, 12, 6, 3 and 1.5 Cycles/Degree from 100% to 0.8% contrast
Normative data study conducted in 2010 by Illinois College of Optometry
All targets are precisely sized according to the testing distance for maximum accuracy
Test in under 5 min
Perfect for monitoring progression of cataracts and assessing quality of vision
Display a graph comparing your patient’s results to normative data at the end of the testing algorithm
Read More
Inquire
Compare
for selected.
Colenbrander Mixed Contrast Reading Card
Precision Vision®
Features:
Mixed high-contrast and 10% contrast
Unrelated simple sentences at 4th grade level
Serves as an educational tool to demonstrate the effect of contrast deficits to patients and family members.
Multi-distance testing
Acuity range 10m to 0.6m in Times Roman Font (20/320, 6/95 to 20/16, 6/4.8 equiv.)
Includes test instructions and diopter ruler
Measures 43 x 38 cm (17 x 11 in.)
Folds in half to 21.5 x 38 cm (8.5 x 11 in.)
Also available in various languages
Read More
Inquire
Compare
for selected.
Colenbrander Reading, Intermediate and Computer Chart (2 card set)
Precision Vision®
Features:
Calibrated for 40 cm (16 in), 63 cm (25 in), 100 cm (40 in)
Measures 8.5" x 11"
Includes complete instructions and recording sheet
Uses 10% calibrated Contrast Sensitivity level with Acuity
Read More
Inquire
Compare
for selected.
Complete Rabin Contrast Sensitivity Set
Precision Vision®
Features:
A new contrast sensitivity test comparable to the small letter contrast test
Detects subtle effects of defocus, low luminance and glare
20/50 letter size at 4 meters (13 ft.)
Log CS increases 0.25 steps per row (0.05 log CS/ letter)
Includes soft-tipped pointer, recording forms and test instructions
Read More
Inquire
Compare
for selected.
Low Contrast and Mixed Contrast Eye Charts
Precision Vision®
Features:
Inquire
Inquire
Compare
for selected.
Mars Letter Contrast Sensitivity Test
Precision Vision®
Features:
Three charts, for the left eye, right eye and binocular testing, or for repeated testing without letter sequence memorization
Rapid administration, with easy, accurate scoring
Easy to store and protect
Easy to illuminate (e.g., with instrument stand lamp)
Each chart mounted on durable plastic
Designed for near testing (40 or 50 cm)
Low cost
Read More
Inquire
Select All
Select up to 5 products from above to compare or request more information.
Compare
Showing 15 of 23 products
<<
<
1
2
>
>>
Tags:
Please Login or Register to Create Tags
Feedback
Articles
M&S Technologies Releases Version 2 of Clinical Trial Suite
Help
Use this product listing in multiple ways:
Click
Get Quote
to receive a quote from the vendor for that product
Check up to 5 products and click to
compare
to view product specifications side by side or
Get quote
to get a quote for all your selected products
Click
Get quotes for all products
at the top of the list to get a quote for all products
advertisement
Related Articles
Over 4 Million U.S. Adults Have Glaucoma According...
Friday, November 01, 2024
Epioxa™ Shows Efficacy in Treating Keratoconus in ...
Friday, October 25, 2024
6-Year Data Demonstrates Effective IOP Reduction ...
Wednesday, November 15, 2023
Global Survey Reveals Misconceptions around ...
Thursday, June 22, 2023
The Effectiveness of Cryopreserved Amniotic ...
Wednesday, May 10, 2023
AdGlare RMR2