Pocket Tonometers

CompanyIcare USAReichert TechnologiesReichert TechnologiesNeuvas, Inc.
ItemIcare TonometerTono-Pen AVIA® Applanation TonometerTono-Pen® XL Applanation TonometerTonoPach™
PriceInquireInquire
Vendor Product PageCompany Product Page
DescriptionThe Icare tonometer is based on a proven accurate measuring principle, in which a very light probe is used to make momentary and gentle contact with the cornea. The measurement is barely noticed by the patient and has no corneal reflex. The device Reichert's Tono-Pen AVIA® Handheld Tonometer builds on all the features that make the classic Tono-Pen® XL the clinicians’ choice for the past 30 years. Calibration-free, the AVIA is always ready to provide fast, accurate and reliable IOP The Tono-Pen XL Applanation Tonometer is an easy-to-use, handheld instrument that provides IOP readings that correlate closely with Goldmann Tonometry. Tono-Pen XL's lightweight ergonomic design and advanced electronic measurement technology enable The TonoPach™ is a device intended for highly accurate measurements of intraocular pressure (IOP). IOP remains the single most important metric for the diagnosis and treatment of glaucoma. However, as discovered in a large, randomized, five-year
FeaturesREVOLUTIONARY, EASY ROUTINE
The easy-to-use Icare® tonometers revolutionarize effective, early glaucoma detection and control by making the IOP measuring routine quick, effortless and effective.

SAFE, PAINLESS AND HYGIENIC PROCEDURE
No anesthetic or disinfection is needed with the Icare® tonometer. As a result, the patient flow can be kept dynamic with this time efficient instrument.

SUITABLE FOR ANY KIND OF PATIENT
The Icare® tonometer’s disposable probe touches the cornea very lightly for only a fraction of a second. The measurement is barely noticeable by the patient and therefore suitable even for non-compliant subjects, such as children. Safe for LASIK, corneal and cataract surgery patients with no epithelial or corneal disruption, retina and difficult to applanate patients.

WORLD WIDE APPROVALS AND PATENTS
Icare® has world wide official approvals (CE, US FDA, SFDA etc.) and satisfied users in over 50 countries. Clinical studies* show that the data obtained by Icare® is fully comparable to measuring results obtained with the GAT. Our devices have several unique patented features only available with Icare® Tonometers
  • Accurate IOP measurements correlating strongly with Goldmann
  • Handheld and lightweight
  • One-button operation
  • Uses genuine Ocu-Film® + Tip Covers
  • No calibration required
  • Large dual displays
  • Modern ergonomic design
  • Long-life battery
  • On-screen battery indicator
  • Soft-touch grips
  • 25 years of clinically proven accuracy and reliability
  • Rapid, accurate and objective IOP measurement
  • Functions in any position
  • Portable and extremely light weight
  • Easy-to-read LCD display
The TonoPach’s patented technology combines CCT and IOP in a single, inexpensive, easy-to-use instrument. The TonoPach has been designed to measure intraocular pressure in millions of patients who are presently improperly diagnosed for glaucoma and ocular hypertension.
ApprovalInquireUSUS FDAUS FDA
Product NumberInquire230650230635Inquire
Weight155 g (With out batteries)2.4oz. (71 g)2.1 oz (59.4 g)Inquire
Measurement Range7 to 50 mmHg5 - 55 mmHg5 - 80 mm HgInquire
Measuring IncrementInquireInquireInquireCCT and IOP
Power Source4 x AA batteriesTono-Pen AVIA Powercel Battery Pack2 Ocu-Cel XL BatteriesInquire
Dimension(WxDxH) (13 to 32) x (45 to 80) x 230 mmWidth: 0.75 in. (2 cm)
Length: 6.25 in. (16 cm)
Thickness: 1.75 in. (4.4 cm)
Width: 1 in. (2.5 cm)
Length: 7.25 in (18.4 cm)
Thickness: 0.875 in (2.2 cm)
Inquire
Get quoteInquireInquire