Yag Laser Capsulotomy is a procedure intended to correct posterior capsule opacity. This can occur after cataract surgery when the capsule becomes cloudy because of healing scar tissue. This is a fairly common condition post-operatively. The Yag Laser creates a tiny hole in the posterior membrane to allow the passage of light through and to restore clear and unobstructed vision. This laser is also used for the treatment of other ophthalmological treatment such as acute closed-angle glaucoma.
Most Yag Lasers are semi-portable and intended to be used from room to room for outpatient procedures. As with any surgery, there are risks including detachment of the retina, however, overall these lasers are very safe and boast a simple to use approach.
|  |
Company | Quantel Medical |
Item | Optimis Fusion SLT/YAG Laser |
Price | Inquire |
Vendor Product Page | Company Product Page |
Features | Quantel Medical’s proprietary technology is based on an engineering breakthrough, which enables infrared and visible green nanosecond pulses to be produced by single dual-mode cavity: 532nm and 1064nm. This last technology reduces complexity and results in a more elegant, advanced combination laser platform. Optimis Fusion includes convergent optical path allowing an optimized visualization of both anterior and posterior segment, a better visual comfort, combined with a blue-free LED illumination. A Glaucoma, Cataract and Retina Laser in One : Optimis Fusion easily combines with Quantel Medical Vitra or Vitra Multispotgreen photocoagulators. Main characteristics: - Advanced technology: dual-mode laser cavity, 532nm and 1064nm
- Premium Optics
- Integrated platform with a compact footprint
- A Glaucoma, Cataract and Retina Laser platform combined with Vitra or Vitra Multispot
|
Approval | US FDA |
Weight (lbs) | 24.15 kg (53.1 lbs) |
Portability | No |
Magnification | 3 positions: 10x, 16x, 25x |
Spot Size | - SLT: 400 microns
- YAG: 10 microns (86.4% energy in diameter) - 8 microns FWHM
|
Pulse Duration | 4 ns |
Repetition Rate | - SLT: Up to 2.5 Hz
- YAG: Up to 2 Hz
|
Power Requirements | 100-240 VAC, 50/60 Hz |
Laser Source | - SLT: Q-switched, frequency doubled Nd:YAG
- YAG: Q-switched Nd:YAG
|
Dimensions (W × H × D) | - 54 cm x 64.7 cm x 48.5 cm
- 21.3" x 25,5" x 48.5"
|
Aim Beam | Red 635 nm, adjustable intensity |
Laser Wavelength | |
Pulse Mode | - SLT: Single pulse
- YAG: 1, 2 and 3 pulses per shot
|
Offset | YAG : -150 µm, +30 µm, + 150 µm |
Description | Optimis Fusion combines traditional YAG photodisruption treatments and advanced SLT photoregeneration therapy in one integrated platform. |
Get quote | Inquire |