Designed to assess the clarity and sharpness of a patient’s visual abilities, visual acuity testing systems are based on having the patient view a chart of optotypes, colors or patterns. A standard part of most exam lanes, visual acuity tests can take a number of forms. At their simplest, these tests can be preprinted cards or charts that can be hung or projected on a wall. However, newer digital visual acuity testing systems are built around computer monitors which allow the system to feature a large number of vision tests that can be accessed via remote control and set up for direct or mirrored viewing. Whether evaluating a new patient or conducting a post-op assessment, a visual acuity testing system can be an important part of a practice.
Get quotes for all products
Select up to 5 products from below to compare or request more information.
Featured products
- Network Interface: Inquire
- Weight: Inquire
- Display: Inquire
- Power Requirements: Inquire
- Dimensions (W x H x D): Inquire
- Refraction Range: Inquire
- Max Illumination: Inquire
- Features: Advanced space-saving refraction for efficient workflow
The enhanced capabilities of the TS-610 best serve operators who need the highest refractive performance.
This all-in-one workstation will exceed your expectations for subjective refraction capabilities. The expanded network capability improves usability and adapts to various usage situations.
Simple and reliable refraction in an attractive design
The TS-310 will provide reliable, standard examination with simple, core functions.
Super space-saving design of the TS-310 offers flexible room arrangement without compromising the precision needed in every refraction.
Reliable chart unit
The TS series uniquely uses the same high resolution charts for both distance and near testing. Switching between distant and near is smoothly achieved with a single button push.
Flexible measurement options
Regardless of personal measurement style, or sitting/standing ergonomic preferences, the TS series ensures comfortable refractive examinations for patients and operators alike.
Easy installation
The TS series does not require complex angle and distance adjustments during installation, which can be achieved by any staff member without expert knowledge. It can be easily transported and installed in any facility including eyecare practices, clinics, mobile optometric vehicles, and care facilities for temporary use.
Available for the TS-610
User-friendly control console
The 10.4-inch color LCD touch screen displays a great deal of information including near chart images, refraction diagrams, eye diagram, visual images as viewed by impaired eyes, NIDEK OPD-Scan III summary, and amsler grid.
Empowered Refraction Solution
NIDEK offers our Empowered Refraction Solutions as options to enhance the performance of the people involved with eye examination.
- Fully Assisted Refraction System
The Fully Assisted Refraction System (FARS) is an optional kit for the NIDEK Tabletop Refraction System TS-610, used to determine the full correction by the patient’s response based on objective data or glasses data input by the staff. The kit consists of a joystick controller and the Fully Assisted Refraction System application software. This system brings the efficiency of the refraction and contributes to the improvement of the workflow and staff allocation in a facility.
- RT-6100 CB for Windows
RT-6100 CB for Windows is an optional software for the RT-6100, that enables control using a Windows computer/tablet. This software delivers the comprehensive examination capabilities of the existing control console.
* The computer and tablet are not included or sold. Microsoft and Windows are registered trademarks or trademarks of Microsoft Corporation in the United States and other countries.
Available for the TS-310
Operation-rich control box
The 5.7-inch color LCD touch screen displays all data with high visibility. Simple, understandable, and comfortable user interfaces ensure an effective operation.
- Type: Inquire
Read More
- Network Interface: Inquire
- Weight: Inquire
- Display: Inquire
- Power Requirements: Inquire
- Dimensions (W x H x D): Inquire
- Refraction Range: Inquire
- Max Illumination: Inquire
- Features:
- Randomizes optotypes and eliminates patient memory effect
- Calibrates for long, short, or folded exam rooms
- Wide Dynamic Range, High Sensitivity
- Resolves to sub-pixel accuracy
- A pediatric version is available with a suite of appealing optotypes-tumbling E's and C's, cartoons and tests
- Type: Inquire
Read More
- Network Interface: Inquire
- Weight: Inquire
- Display: Inquire
- Power Requirements: Inquire
- Dimensions (W x H x D): Inquire
- Refraction Range: Inquire
- Max Illumination: Inquire
- Features:
- Flexible system integration
- Selectable working distance
- Smart display function
- Contrast test
- Night mode
- Indication of a slide image
- Type: Inquire
Read More
- Network Interface: Inquire
- Weight: Inquire
- Display: Inquire
- Power Requirements: Inquire
- Dimensions (W x H x D): Inquire
- Refraction Range: Inquire
- Max Illumination: Inquire
- Features:
- Visual Acuity Test -
With Landolt rings (in acc. with DIN EN ISO 8596), numbers, letters, tumbling E and acuity symbols for children (optional).
New: Now also ETDRS Charts are available for the visual acuity test. -
Color Vision Test -
Large selection of color plates according to Ishihara and Velhagen-Broschmann colour test plates. The display is calibrated to the exact color temperature, thus guaranteeing ideal color rendering. -
Binocular Test -
The binocular vision tests are generated by a modern LCD shutter system, which is very similar to natural visual conditions. Furthermore, a variety of stereo-vision and phoria tests guarantees a reliable evaluation of the binocular vision functions. -
Contrast Sensitivity Test -
A program for testing contrast sensitivity under photopic conditions is also integrated. The contrast sensitivity test can be conducted at various visual acuity levels with Landolt rings, letters and numerals as options. -
Mesopic Vision and Glare Sensitivity -
Visual performance varies in different light conditions.
To test visual function under mesopic conditions, a Landolt ring is presented in an environment of low light density (0.032 cd/m²), corresponding to the situation of night driving. The Landolt ring (visual acuity level 20/200) is presented in four different contrast stages (1:23 / 1:5 / 1:2.7 / 1:2). Glare sensitivity is tested by simulating the dimmed light of an approaching vehicle. The test with this glare light is also conducted in the four contrast stages.
New: Due to additional corrective lenses in the range of -0,5 D to -3,5 D the possibility to check night myopia is now available. -
Peripheral Visual Field Test -
The visual field is tested at seven visual field locations at the right and at the left. Fixation control is done by means of a changing fixation mark in the center of the test screen. -
Additional Corrective Lenses -
If asthenopic symptoms are present or if the visual acuity values are abnormal, the additional corrective lenses in the range of +4,5 D to -3,5 D can be used to determine whether an undetected (latent) hyperopia (up to +1,5 D), an age-related long sightedness (presbyopia) or myopia, especially night myopia, exist. -
Range of Accommodation Measurement -
Measurement of the range of accommodation can be a valuable tool for deciding whether special eyeglasses for computer users are needed. The Duane test figure makes a speedy and informative measurement possible. -
Optotypes for Children -
In addition to the tumbling-E test, additional optotypes for testing the visual acuity of children have been added. These are based on the H-test optotypes.
- Type: Inquire
Read More
- Network Interface: Inquire
- Weight: (unpacked) 10 lbs. (4.5 Kg)
- Display: 19 in. (48.26 cm) LED backlight LCD
- Power Requirements: 100 - 240 volts AC 50/60 Hz 70-95 VA
- Dimensions (W x H x D): 19.88 in. x 16.91 in. x 3.25 in
- Refraction Range: 6 ft (1.83 m) - 31 ft (9.5 m)
- Max Illumination: 220 cd/m2
- Features:
- Configure for direct or mirror viewing
- Large range of optotypes
- Three different sets of children's optotypes
- Random sequencing of optotypes
- Special test charts for astigmatism testing, suppression and fixation
- Contrast Sensitivity testing with sine-wave grating or contrast optotypes
- Complies with ETDRS protocol
- Adjustable red/green for compatibility with any refraction system
- Hearing Impaired Mode
- Cartoon loop with sound for pediatric fixation
- Patient education slides
- Integrates seamlessly with the Reichert Phoroptor VRx, Reichert Auto Phoroptor RS, Visutron 900+, and Visutron 900 Touch.
- Made in the USA
- Type: Digital
Read More
Stereo Optical Company, Inc.
- Network Interface: Inquire
- Weight: Inquire
- Display: Inquire
- Power Requirements: Inquire
- Dimensions (W x H x D): Inquire
- Refraction Range: Inquire
- Max Illumination: Inquire
- Features:
- Remote controlled and uses color corrected lighting
- Requires only 2 square ft. of space, is lightweight and portable, weighs less than 15 pounds
- Contrast sensitivity slide packages are available at an additional cost
- Type: Digital
Read More
Stereo Optical Company, Inc.
- Network Interface: Inquire
- Weight: Inquire
- Display: Inquire
- Power Requirements: Inquire
- Dimensions (W x H x D): Inquire
- Refraction Range: Inquire
- Max Illumination: Inquire
- Features:
- Instruments are manually controlled & color corrected
- Requires 2 square ft. of space, is lightweight and portable, and weighs less than 15 lbs
- Contrast Sensitivity and Peripheral Tests are optional, as well as customized slide packages
- Instrument is available in 2 models: Optec® 5000P includes a peripheral test. Optec*reg; 5000 does not.
Type: Digital
Read More
Stereo Optical Company, Inc.
- Network Interface: Inquire
- Weight: Inquire
- Display: Inquire
- Power Requirements: Inquire
- Dimensions (W x H x D): Inquire
- Refraction Range: Inquire
- Max Illumination: Inquire
- Features: Easy to use and intuitive interface
- Control your test on a single screen
-
Choose your test conditions in one click - Night and Day, Monocular L&R, Binocular, Far, Intermediate, Near distance selection or Random
-
Change your selection at any time
Customization : Creating your own protocol is simple
- Design and record your own protocol
- Optometry screening
-
Occupational medicine
-
Driver rehabilitation
-
Sports/Athletics
-
F.A.A.
-
Public Health, Primary Care
-
Schools, Pediatrics
-
Modify your preset protocols during screening
-
All tests can be randomized
Automatic mode : Increase the efficiency of your patient flow and same time in the exam lane
- With this unique feature, the tests can be Self administered by the patient or Delegated to your staff
- Test to speech technology guides patient through the test, freeing you from repetitive tasks
-
Preset auto-mode protocols
- The Optec® Plus records the patient results for you
Connectivity : Get all the advantages of a Smart Device
- Digital records in .pdf file or .xml that can be printed, extracted and exported
-
EMR compatibility to ease your data transfer
-
Operated and monitored on – PC, Laptop, Tablet, Wireless connectivity: Bluetooth and Wifi
- Type: Inquire
Read More
- Network Interface: Inquire
- Weight: Inquire
- Display: Inquire
- Power Requirements: Inquire
- Dimensions (W x H x D): Inquire
- Refraction Range: Inquire
- Max Illumination: Inquire
- Features:
- Safe-distance
- Small space requirements
- Less components
- Type: Inquire
Read More
- Network Interface: Inquire
- Weight: Inquire
- Display: Inquire
- Power Requirements: Inquire
- Dimensions (W x H x D): Inquire
- Refraction Range: Inquire
- Max Illumination: Inquire
- Features:
- Stand alone visual testing system
- Modern 17" flat panel
- Wireless remote control
- Flexible mounting options - wall or desk
- Forward or reversed for mirrored rooms
- Wide array of charts including ETDRS
- Contrast sensitivity testing
- Customizable onscreen scripts
- Meets ANSI and ISO standards for vision testing
Type: Digital
Read More
Good-Lite (Formerly Richmond Products, Inc.)
- Network Interface: Inquire
- Weight: Inquire
- Display: Inquire
- Power Requirements: Inquire
- Dimensions (W x H x D): Inquire
- Refraction Range: Inquire
- Max Illumination: Inquire
- Features:
- Substantially increased the uniformity of illumination across the entire 550 sq. cm test area
- Improved the durability of the chart - now printed on styrene
- Increased bulb life span by 10 times using LED illumination
- Compact, Universal power supply (110/220 50/60 Hz)
Type: Inquire
Read More
Inquire
- Network Interface: Inquire
- Weight: Inquire
- Display: Inquire
- Power Requirements: Inquire
- Dimensions (W x H x D): Inquire
- Refraction Range: Inquire
- Max Illumination: Inquire
- Features: Inquire
- Type: Booklet
Read More
Inquire
- Network Interface: Inquire
- Weight: Inquire
- Display: Inquire
- Power Requirements: Inquire
- Dimensions (W x H x D): Inquire
- Refraction Range: Inquire
- Max Illumination: Inquire
- Features:
- Track changes in visual acuity levels from visit to visit
- Proprietary technology to allow testing at 3 meters, 1 meter and 25 centimeters
- Measures black-white discrimination in patients with acuity below 20/16000
- Visual acuity thresholds to 20/20000
- System controlled by any M&S-produced input device
- Conforms to all ANSI, ISO and FDA guidelines for Visual Acuity testing
- Provides for consistent and repeatable results
- Patient results can be printed; can be stored locally or transferred to any media storage device
- Utilizes Smart System® integrated database to store and transmit test results within minutes of test completion via internet connections
Type: Digital
Read More
Inquire
- Network Interface: Inquire
- Weight: Inquire
- Display: Inquire
- Power Requirements: Inquire
- Dimensions (W x H x D): Inquire
- Refraction Range: Inquire
- Max Illumination: Inquire
- Features:
- Testing for CSF Under Glare Conditions at low, medium or high luminance levels. Can be performed at either mesopic or photopic luminance levels
- Preferred Optotypes; Rotationally symmetric targets and randomly presented optotypes. Eliminates biases from the patient with non-rotational symmetric optical aberrations such as residual astigmatism, trefoil, coma, etc.
- ANSI & ISO Guideline Conformance; Conducts contrast sensitivity testing at (1.5, 3, 6, 12 and 18) cycles per degree and at light levels of 85 cd/m2 (photopic) and 3 cd/m2 (mesopic). Plus, includes all of the options and parameters the agencies require for contrast testing
- Conduct Standard Vision Testing; Integrate with the M&S Smart System comprehensive visual acuity, contrast sensitivity, fixation and video display systems. Approved for clinical trials using the eETDRS and ATS protocols for visual acuity
- Quick Test Feature that reduces test time on patient return visits by starting at 0.3 log units above previous threshold, minimizing test time to less than 3 minutes per eye
- Automated-user interactive testing eliminates technician bias or erroneous data
- Store multiple test results by patient to track changes in CSF function over time; results can be stored locally or transferred to any media storage device
- Graph, compare and print patent results against normative data
- Utilizes Smart System integrated database to store and transmit test results within minutes of test completion via internet connections
Type: Digital, Automated
Read More
Inquire
- Network Interface: Inquire
- Weight: Inquire
- Display: Inquire
- Power Requirements: Inquire
- Dimensions (W x H x D): Inquire
- Refraction Range: Inquire
- Max Illumination: Inquire
- Features:
- Utilize automated protocol that provides results with normative data or manually test patients using the M&S Remote Control or Keypad
- Measure contrast at ANSI Standard 18, 12, 6, 3 and 1.5 Cycles/Degree from 100% to 0.8% contrast
- Normative data study conducted in 2010 by Illinois College of Optometry
- All targets are precisely sized according to the testing distance for maximum accuracy
- Test in under 5 min
- Perfect for monitoring progression of cataracts and assessing quality of vision
- Display a graph comparing your patient’s results to normative data at the end of the testing algorithm
Type: Digital
Read More
Inquire
Select up to 5 products from above to compare or request more information.
Tags:
Please Login or Register to Create Tags
Articles
- M&S, Topcon Partner on Computerized Vision Testing Systems
- TS-610/310 Tabletop Refraction System
- 2015 OphthalmologyWeb Videos Review
- UV Nexus Visual Acuity System
- New Research Says Nerve Cell Injury May be to Blame for Diabetes-Related Vision Loss
- Risk of Blindness from Spinal Fusions Declines
- Number of Vision-Related Projects Named Finalists for Google Science Fair
- Avedro Releases Promising PiXL Procedure Study Results
- "SIGHT: The Story of Vision" Debuts Starting Today
- Ophthalmologist Named Rolex Awards Laureate
- CooperVision Shares Interim Results for Myopia Control Contact Lens Clinical Trial, Raises $164,000 for Optometry Giving Sight
- Utah Engineers Develop Smart Glasses with Automatic Focus Adjustment
- International Research Team Develops New Cell Culture Model for Earlier AMD Treatment
- Study Finds Brains of Those Born Blind "Rewire" Themselves to Boost Other Senses
- Stereo Optical Adds Tests to Optec Plus
- Researchers New Understanding of Brain's Visual Process May Help Develop Therapies for Sensory Impairment
- RestoringVision Aims to Return Sight to 20M People by 2020
- High School Student Wins International Healthcare Challenge with Ophthalmology Project
- Broccoli-Related Compound May Hold Key in Treating AMD
- Study Says Diabetic Vision Loss On the Rise Globally
- New Report Issues Call to Action to Eliminate Correctable, Avoidable Vision Impairment by 2030
- AAO 2016 Meeting Highlights — Part II
- Stereo Optical Launches Optec Plus Smart Vision Screener
- Study Suggests What We See in Peripheral Vision May Sometimes Be an Illusion
- AAO, Lighthouse Guild, Bookshare Partner for Online Assisted Reading Library for Visually Impaired Students
- UW Scientists Uncover How the Fovea Functions
- Prevent Blindness Announces 2017 Summit, Working with Allergan for See America Initiative
- Researchers Find Link Between Ethnicity and Visual Function in AMD Patients
- New 3D Display Could Help Eliminate Eye Fatigue Issues with AR Glasses
- Humira Receives FDA Approval for Non-Infectious Intermediate, Posterior and Panuveitis
- New Study Shows Reduced Vision Has Negative Impact on Quality of Life
- Duke Health Study Finds Humira Effective Treatment for Noninfectious Uveitis
- Ophthalmologist Wins Bayer Global Award
- M&S Technologies CTS Glare Testing Unit Meets ANSI Standard, DataRight Module Now Available
- UofL Researcher Receives Grant for Amblyopia Research
- More Time Outdoors May Lead to Reduced Myopia in Teens and Young Adults
- Humayun Named Keynote Speaker for 2017 Envision Conference
- UT Southwestern Researchers Find Potential Way to Prevent Vision Deterioration in Space
- Lighthouse Guild Honors Researchers for Outstanding Achievements in Vision Science Research
- M&S Technologies Releases Version 2 of Clinical Trial Suite
- Brien Holden Vision Institute, WHO Release New Report on Myopia and High Myopia
- Researchers Find Link Between Myopia and Education Levels
- New Study Shows Poor Vision Can Cause Physical Decline, Cognitive Issues in Older Adults
- UChicago Receives Grant to Build Visual Prosthesis
- Guardion Health Sciences to Acquire VectorVision
- Researchers Given Grant to Help Identify Causes of Astronaut Eye Pathologies
- New Research Suggests Underdiagnosis of AMD Not Uncommon in Primary Eye Care
- Magnets Implanted Behind Eyes Successful in Treating Nystagmus
- Special Glasses To Help Patients with Color Blindness
- NEI Study Shows Intensively Controlling Blood Sugar Levels Can Lower Diabetic Retinopathy Risk
- Essilor Launches Innovation Challenge to Help Improve Access to Vision Care