YAG lasers are often used for Capsulotomy and Trabeculectomy procedures. Yag Laser Capsulotomy is a procedure intended to correct posterior capsule opacity whereas Trabeculectomy is a procedure used in Glaucoma patients to relieve intraocular pressure via YAG laser. A Capsulotomy is necessary when the capsule becomes cloudy because of healing scar tissue. This is a fairly common condition post-operatively. The Yag Laser creates a tiny hole in the posterior membrane to allow the passage of light through and to restore clear and unobstructed vision. A Trabeculectomy or SLT (Selective Laser Trabeculectomy) is partial removal of the trabecular meshwork and surrounding areas to drain excess fluid and relieve pressure.
Many YAG lasers on the market now boast the dual features that enable an Ophthalmologist to perform both Capsulotomy and Trabeculectomy procedure via one laser. This allows an Ophthalmology practice to utilize available space and decrease the amount of large equipment needed. Many of these YAG lasers offer upgradable features that are available to add on at a later date, insuring your practice stays up to date.
Select up to 5 products from below to compare or request more information.
Featured products
- Features: A suite of technologies has been incorporated in these lasers to achieve seamless function and greater precision. Features for targeting pathology, accurate energy delivery, and operative assist functions allow the surgeon to deliver treatments “Right on the Mark”.
- Refined Laser Delivery with Lower Energy
The YC-200 S plus / YC-200 achieves 1.6 mJ plasma threshold in air*, delivering accurate and robust treatments with lower energy.
*A plasma threshold of 1.6 mJ is achieved in ordinary room conditions (in-house data).
- SLT-NAVI*
The SLT-NAVI feature presents an intuitive display on the progress of laser treatment, providing the surgeon with important feedback.
*Available for the YC-200 S plus
- Clear and Sharp Field of View
An improved optical design that optimizes resolution and contrast, and an expanded focal depth provide a clear view of pathology and treatment.
- Precise Aiming Beam
Motorized Rotatable Aiming Beam (YAG Mode)
The dual aiming beam offers superior targeting with a 360° rotating aiming beam that can avoid corneal opacities and achieve more accurate focusing.
Precise Edge Aiming Beam (SLT Mode*)
Parfocality delivers a clear view for easier focusing of the aiming beam through the contact lens.
*Available for the YC-200 S plus
- Optimized Operating Distance*
Maximized working distance allows easier manipulation of the contact lens, and the short operating distance decreases surgeon fatigue during treatment.
*Operating distance denotes the distance from the microscope eyepiece to the patient’s eye.
- Unique Joystick
Utility S-switch
The S-switch on the joystick changes treatment settings without shifting gaze from the oculars. The ease of use allows surgeons an increased level of comfort during treatment.
- Mode: Inquire
- Weight (lbs): Inquire
- Magnification: Inquire
- Slit lamp: Inquire
- Spot Size: Inquire
- Cooling System: Inquire
- Pulse Length/Width: Inquire
- Repetition Rate: Inquire
- Electrical Requirements: Inquire
- Dimensions (W × H × D): Inquire
- Aiming Beam: Inquire
- Treatment Laser Type: Inquire
- Laser Wavelength: Inquire
- Laser Energy: Inquire
- Exit Aperture Angle: Inquire
- Burst Mode: Inquire
- Cone Angle: Inquire
- Offset Focus: Inquire
Read More
- Features: Quantel Medical’s proprietary technology is based on an engineering breakthrough, which enables infrared and visible green nanosecond pulses to be produced by single dual-mode cavity: 532nm and 1064nm.
This last technology reduces complexity and results in a more elegant, advanced combination laser platform.
Optimis Fusion includes convergent optical path allowing an optimized visualization of both anterior and posterior segment, a better visual comfort, combined with a blue-free LED illumination.
A Glaucoma, Cataract and Retina Laser in One :
Optimis Fusion easily combines with Quantel Medical Vitra or Vitra Multispotgreen photocoagulators.
Main characteristics:
- Advanced technology: dual-mode laser cavity, 532nm and 1064nm
- Premium Optics
- Integrated platform with a compact footprint
- A Glaucoma, Cataract and Retina Laser platform combined with Vitra or Vitra Multispot
- Mode: Inquire
- Weight (lbs): 24.15 kg (53.1 lbs)
- Magnification: 3 positions: 10x, 16x, 25x
- Slit lamp: Inquire
- Spot Size:
- SLT: 400 microns
- YAG: 10 microns (86.4% energy in diameter) - 8 microns FWHM
- Cooling System: Air cooled
- Pulse Length/Width: Inquire
- Repetition Rate:
- SLT: Up to 2.5 Hz
- YAG: Up to 2 Hz
- Electrical Requirements: 100-240 VAC, 50/60 Hz
- Dimensions (W × H × D):
- 54 cm x 64.7 cm x 48.5 cm
- 21.3" x 25,5" x 48.5"
- Aiming Beam: Red 635 nm, adjustable intensity
- Treatment Laser Type:
- Laser Wavelength:
- Laser Energy: Inquire
- Exit Aperture Angle: Inquire
- Burst Mode: Inquire
- Cone Angle: Inquire
- Offset Focus: Inquire
Read More
Inquire
- Features:
- Two defocus positions that can easily be changed with a roll of your finger
- Sophisticated focusing system ensures superior accuracy in energy placement
- Advanced precision optics offer maximum visibility for more precise diagnosis and treatment
- Compact and lightweight design optimizes the physician's working space
- Mode: Fundamental Q-Switched
- Weight (lbs): System: 46.3 lbs (21 kg)
- Magnification: 5 Steps: 6x, 10x, 16x, 25x, 40x
- Slit lamp: CSO SL 950
- Spot Size: 8 µm
- Cooling System: Air convection
- Pulse Length/Width: 4 nanseconds (typical)
- Repetition Rate: 2.5 Hz
- Electrical Requirements: 100V - 240V AC, 50/60 Hz
- Dimensions (W × H × D): 12.5 in (32 cm) x 20.5 in (52 cm) x 17.7 in (45 cm)
- Aiming Beam: Dual beam 635 nm diode continously variable intensity to 200 µm
- Treatment Laser Type: Nd:YAG
- Laser Wavelength: 1064 nm
- Laser Energy: Continously adjustable from 0.2 to 10 mJ
- Exit Aperture Angle: Inquire
- Burst Mode: 1, 2, 3 pulses each burst; separation between pulses is 20 µs
- Cone Angle: 16 degrees
- Offset Focus: Continously variable from anterior (-)500 µm to posterior (=)500 µm; detent steps @ 0, 150, 250, 500 µm
Read More
Inquire
- Features:
- True Portability
- Maximum Space Utilization
- Compatible with most commercially available converging-optics style slit lamps
- Mode: Inquire
- Weight (lbs): 25 lbs (11 kg)
- Magnification: Inquire
- Slit lamp: Compatible with most commercially available converging-optics style slit lamps
- Spot Size: 400 microns
- Cooling System: Air cooled
- Pulse Length/Width: Inquire
- Repetition Rate: 3Hz
- Electrical Requirements: 100 -240 VAC, 50/60 Hz, 3.15 Amps
- Dimensions (W × H × D): Inquire
- Aiming Beam: Red Diode, continuously variable
adjustable intensity
- Treatment Laser Type: Inquire
- Laser Wavelength: Inquire
- Laser Energy: Inquire
- Exit Aperture Angle: Inquire
- Burst Mode: Inquire
- Cone Angle: Inquire
- Offset Focus: Inquire
Read More
Inquire
- Features:
- Proprietary advanced laser design, with automatic internal tests to ensure power requirements and a secondary control unit to guarantee power accuracy.
- Highly-accurate Super Gaussian beam profile in YAG mode
- Table is equipped with built-in compact storage space for lenses or other accessories
- Ergonomically designed joystick includes a convenient integrated laser fire-switch.
- Three posterior defocus positions with an adjustable focal point of up to 350 posterior to the aiming beam.
- Slit lamp function includes a 6-step magnification changer.
- Table height can be easily adjusted using its electronic up/down switch
Mode: InquireWeight (lbs): <60 kg>60 kg>Magnification: InquireSlit lamp: InquireSpot Size: YAG: 8 microns
SLT: 400 micronsCooling System: Air cooledPulse Length/Width: InquireRepetition Rate: YAG: 3Hz (in single burst)
SLT: 3HzElectrical Requirements: 100 -240 VAC, 50/60 Hz, 3.15 AmpsDimensions (W × H × D): InquireAiming Beam: Red Diode, continuously variable adjustable intensityTreatment Laser Type: InquireLaser Wavelength: InquireLaser Energy: InquireExit Aperture Angle: InquireBurst Mode: InquireCone Angle: InquireOffset Focus: Inquire
Read More
Inquire
- Features:
- Homogeneous Laser Beam in Photo-Coagulator mode
- Dual Fiber Port -- Instantly switch between delivery devices
- ClearView™ Filters -- Optimized view of treatment site
- AcuGuide™ Micromanipulator for accurate and safe laser beam guidance for fine-tuned laser application on target tissue.
- Integrated LaserLink Cradle safely and conveniently stow
- Table is equipped with built-in compact storage space for lenses or other accessories
- The ergonomically designed joystick includes a convenient integrated laser fire-switch.
- Three posterior defocus positions with an adjustable focal point of up to 350 posterior to the aiming beam.
- Slit lamp function includes a 6-step magnification changer.
- Table height can be easily adjusted using its electronic up/down switch.
- Mode: Inquire
- Weight (lbs): Inquire
- Magnification: Inquire
- Slit lamp: Inquire
- Spot Size: YAG: 8 microns
SLT: 400 microns
PC: 50 - 100 on Z-Link; 5-500 on Convrg-Link - Cooling System: Inquire
- Pulse Length/Width: Inquire
- Repetition Rate: YAG: 3Hz (in single burst)
SLT: 3Hz
PC: N/A - Electrical Requirements: 100-240 VAC, 50/60 Hz, 3.15 Amps
- Dimensions (W × H × D): Inquire
- Aiming Beam: Red Diode, continuously variable, adjustable intensity
- Treatment Laser Type: Inquire
- Laser Wavelength: Inquire
- Laser Energy: Inquire
- Exit Aperture Angle: Inquire
- Burst Mode: Inquire
- Cone Angle: Inquire
- Offset Focus: Inquire
Read More
Inquire
- Features: -High operability with S-switch on joystick
The S-switch on the joystick provides changes to treatment settings while maintaining alignment on the region being treated. The convenience of not looking away from the oculars during treatment and ease of use allow surgeons an increased level of comfort during treatment.
-Reliable laser output with unique D-pulse control
The YC-1800 employs D-pulse, the advanced technology to control the pulse number under the CPU, providing stable laser output without being affected by environmental conditions and change over time.
-Dual rotatable aiming beam for accurate alignment
The dual 635 nm aiming beam offers superior targeting, which in turn enhances the speed and ease of surgery. The 635 nm beam is also safer for human eyes because it achieves the same crisp and sharp intensity of 650 nm or 670 nm beam with half the power output. The dual aiming beam can be rotated incrementally up to 360º permitting efficient and precise treatment.
-Wide range of focus shift
Focus shift enables focal point of YAG laser beam to shift within 500 µm in an anteroposterior direction from focal point of aiming beam. It is displayed in 25 µm increments, which allows minute setting to meet various clinical needs.
-Easily upgraded to the YAG/Green Combo system
The combination with NIDEK laser photocoagulator, MC-500, GYC-500, and GYC-1000 allows wide range of treatment and saves space in a operation room. - Mode: Inquire
- Weight (lbs): Inquire
- Magnification: Inquire
- Slit lamp: Inquire
- Spot Size: Inquire
- Cooling System: Inquire
- Pulse Length/Width: Inquire
- Repetition Rate: Inquire
- Electrical Requirements: Inquire
- Dimensions (W × H × D): Inquire
- Aiming Beam: Inquire
- Treatment Laser Type: Inquire
- Laser Wavelength: Inquire
- Laser Energy: Inquire
- Exit Aperture Angle: Inquire
- Burst Mode: Inquire
- Cone Angle: Inquire
- Offset Focus: Inquire
Read More
- Features: Fully Integrated: It is the only system that fully integrates photocoagulation with photodisruption via a Zeiss laser slit lamp.
- System parameters adjustable via anti-reflective touch screen control - Also includes PowerPress control for easy power adjustments.
- Both systems can be used independently at any given time for maximum versatility at your practice.
Premium Photodisruption (YAG III) Features: - High pulse repetition frequency of 2.5Hz enables fast procedures.
- Super-Gaussian beam profile allows typical clinical procedures to be performed with less energy - Optical breakdown can be achieved with as little as 2.5mJ (in air).
- 4-point aiming beam - allows for precise focusing and indicates any astigmatic distortion, allowing for energy adjustments before firing the laser.
- Variable focus shift: 0, +150µm, -150µm.
- Ergonomic design guarantees unobstructed visual contact with the patient and free access to the eye.
Premium Photocoagulation (532s) Features: - True color active physician safety filters coupled with therapy laser - for a brilliant slit lamp image.
- Thermoelectric cooling with enhanced stability management - for reliable and reproducible therapy results without performance fluctuations.
- ParFocus zoom system - delivering a homogeneous, sharply defined and reproducible laser spot to the retina without heat-related side effects on the patients cornea.
- Programmable Parameter Presets.
- Micro-Manipulator, integrated into the slit lamp joystick allows for fast and precise beam positioning and navigation
- Laser and illumination are coaxially synchronized for increased ergonomics
- Mode: Inquire
- Weight (lbs): Inquire
- Magnification: Inquire
- Slit lamp: Inquire
- Spot Size: Inquire
- Cooling System: Inquire
- Pulse Length/Width: Inquire
- Repetition Rate: Inquire
- Electrical Requirements: Inquire
- Dimensions (W × H × D): Inquire
- Aiming Beam: Inquire
- Treatment Laser Type: Inquire
- Laser Wavelength: Inquire
- Laser Energy: Inquire
- Exit Aperture Angle: Inquire
- Burst Mode: Inquire
- Cone Angle: Inquire
- Offset Focus: Inquire
Read More
Inquire
Select up to 5 products from above to compare or request more information.